Matte Application

Heps with NiCu matte with the composition shown below was granulated at about 1200° C with no resulting explosions or damage

FSF Matte Composition

wt%

Ni3S2

59.71

NiS

4.46

Ni

11.71

 Cu2S

14.37

 FeS

9.75

   
 

100.00




The 7m long collecting/containment unit installed in the place of a matte ladle and transport car.

A removable machined graphite tap block was secured to the water cooled copper tap plate as a flow control.

Granulated matte and excess water were conveyed to a concrete bunker via a short suspended vibrating conveyor.

Water drained from the accumulating granulated matte pile into a one cubic meter calibration sump which overflowed to a return water sump.

Granulated matte and excess water coming from the HEPS unit at a ratio of 0.7 : 1 (water/matte).

Granulated matte and excess water coming from the HEPS unit at a ratio of 0.26 : 1 (water/matte).



Film Clips



Granulated matte and excess water exiting a HEPS unit.

Granulated matte and excess water conveyed to the collection bunker.


Double click on the images to start the movies  (1.215 MB each)
Requires Windows Media Player or other MPEG player